Masonry repair
Sweep & inspection
Caps & crowns
Flue relining
Gas fireplace serviceLevel 1 sweep and inspection to the NFPA 211 annual standard - flue, crown, cap, and flashing checked and photographed
Chimney sweep logs do not sweep chimneys. They loosen some creosote - which then falls where a brush and vacuum still have to collect it.
Famco Damper Repair: The Las Vegas Owner’s Guide
A Famco damper repair in Las Vegas typically runs between $165 and $410 installed, depending on the model and whether we’re replacing just the cable, the plate assembly, or the full frame. We stock Famco-compatible dampers and repair kits on the truck, so most jobs are done in a single visit. What usually brings a Las Vegas homeowner to this page is pretty specific: you pull the lever to close the damper and nothing happens. Maybe the cable went slack. Maybe the plate’s frozen halfway open, whistling when the wind picks up off the Spring Mountains. Or you saw a $90 charge on last month’s gas bill and finally traced that draft to a damper that hasn’t sealed right in years.
We work on these often enough in neighborhoods from Summerlin to Green Valley that we can tell you right now: this is rarely a mystery diagnosis. The part’s either worn out, warped, or was installed slightly off to begin with. And the fix is usually straightforward once you’re looking at the right replacement.
Which Famco Models This Applies To
Famco makes several damper lines, and the repair path depends on which one you have. The most common in Las Vegas homes are the Famco C系列 top-sealing dampers (often sold as “Famco Lyemance” style), the Famco anchor-plate dampers for masonry fireplaces, and the Famco V-bolt cast iron dampers found in older wood-burning boxes. Each has different failure points and different replacement parts. The cable-and-pulley mechanism on a top-sealing damper is a different animal from the pivot pins on an anchor plate.
Here’s the compatibility gotcha we run into weekly: the mounting hole spacing changed between Famco production runs around 2018. We’ve seen homeowners order what they thought was the correct plate online, only to find the mounting holes are 3/8 inch off. Before you buy anything, take two measurements: the throat width of your fireplace opening, and the center-to-center distance between the existing mounting bolts. That second number saves more returns than anything else. When you call us, we’ll ask for both. If you’re not sure how to measure, that’s fine. We do it on site anyway.
On the OEM-versus-aftermarket question: for Famco specifically, we’ve had good luck with OEM plates and frames. The aftermarket castings we’ve tested tend to run slightly thinner, and in a Las Vegas summer where your chimney cavity bakes to 140°F, thinner metal warps faster. We stock OEM Famco hardware and a small selection of aftermarket cables, because a steel cable is a steel cable. The plate itself? We’d rather put Famco’s casting back in.
We also carry repair parts for DuraFlex liners, HeatShield, and Gelco, but if it says Famco on the frame, we keep it Famco.
Styles & brands we work with





Signs Your Famco Damper Repair Is Failing
- Lever or cable won’t move at all. Usually a seized pivot pin, a snapped cable end, or heat-warped plate binding against the frame. When the plate binds hard enough, homeowners wrench the lever and crack the casting, which turns a $185 cable job into a $410 plate replacement. If it stops moving, stop pulling.
- Lever moves but the plate doesn’t follow. This is almost always a stretched or detached cable. Famco cables take a beating in Las Vegas because the temperature swing between a winter fire and a July afternoon is brutal on steel cable clamps. The cable stretches, and the plate hangs half-cocked.
- Constant draft with the damper “closed.” Warped plate or deteriorated gasket seating. You’ll feel it strongest on the brick hearth first thing in the morning. Your fireplace is now a two-story window that never shuts.
- Rattling or fluttering during windy days. Common in southern Las Vegas when monsoon winds roll through. The plate’s loose on its pivot, and wind pressure across the chimney top makes it chatter. That’s not normal operation. That’s mechanical slop.
- Visible rust flakes or a seized pivot point during your sweep. We see this in fireplaces that were used heavily for a decade, then left dormant for years. Rust sets in, and the first movement of the season snaps whatever’s still holding.
See the difference
Before
After
Before
After
Before
AfterReplacement Cost & What’s Included
In Las Vegas, a Famco damper repair generally lands in one of three buckets. A simple cable replacement runs $165 to $220. A pivot pin or linkage repair with a new cable runs $190 to $260. A full plate-and-frame replacement runs $280 to $410, with the higher end being the top-sealing models that require ladder access to the chimney crown. These are honest, written prices. We hand you the number before any work starts, and the invoice matches it exactly because it’s the same document.
Every Famco repair we do includes the part, the labor, the trip, and a written guarantee. If that repair fails inside the guarantee period, we come back and correct it at no charge. That’s the 365-Day Done Right Promise from the Kingswell Guarantee. It’s not an add-on line item. It’s just how we write up the job.
| Famco Repair Type | Typical Las Vegas Cost | What’s Included |
|---|---|---|
| Cable or linkage replacement | $165 – $220 | New cable, hardware, in-home test, written guarantee |
| Pivot pin / bracket repair | $190 – $260 | New pins or bracket, cable check, written guarantee |
| Plate and frame replacement | $280 – $410 | New Famco plate, frame seated, written guarantee |
Nathan Corliss built Ashby Chimney on a simple habit: say the price first, explain what you’re doing, and put the promise in writing. We’ve held to that since 2002, and when we’re under a Famco frame in a Summerlin living room, you’ll hear the same words you heard on the phone.
DIY or Call Us?
Here’s the honest split. You can safely clean surface rust off a damper plate with a wire brush if you can reach it through the firebox. You can visually check whether the cable is attached at both ends. You can take the two measurements we mentioned earlier. That’s genuinely useful, and we’ll use those measurements when we show up.
What you shouldn’t do is remove the damper frame yourself. Famco plates sit under tension, and on top-sealing models the spring-loaded cable can snap back hard if you release it the wrong way. We’ve also seen well-meaning homeowners reseat a damper frame slightly out of square, then fight drafts and whistling for three years before they call us. A damper that’s mounted wrong is quieter than a damper that’s broken, but it’s still wrong. If you’re holding a wrench and wondering whether you should apply force to anything near the throat, call (725) 220-6109 instead. We’ll send someone who’s done this in homes across the valley for over a decade, and you’ll get a written price before anything comes off the truck.
FAQs
A properly installed Famco damper lasts 15 to 25 years in Las Vegas, but cables and pivot pins typically need attention at the 10 to 12 year mark because the extreme heat and dry air in the valley degrades the moving parts faster than the castings. If your fireplace has been idle for several years, have the damper checked before the first fire. Call (725) 220-6109 and we’ll inspect it as part of a standard sweep.
Yes, most Famco dampers can be repaired rather than replaced, because the failure is usually a cable, pin, or bracket rather than the cast plate itself. We’ll show you the part in our hands before we swap it, and we only recommend full replacement when the plate is cracked or warped past a safe seal. Get a written price first by calling (725) 220-6109.
Most Famco damper repairs take 45 to 90 minutes on site, including cleaning the seating surface, testing the throw, and checking the draft with a smoke pencil. A top-sealing model that requires crown access adds about 30 minutes for ladder setup. We’re usually in and out in one visit, and the fireplace is ready to use the same day.
Yes, we stock common Famco cables, pins, brackets, and plate assemblies on the truck for the models we see most often in Las Vegas. If you have a less common size, we’ll order the OEM part and come back within the week. Call (725) 220-6109 with your model number or measurements, and we’ll tell you what’s already in the truck.
Written by Nathan Corliss, Owner, Ashby Chimney Las Vegas at Ashby Chimney Las Vegas, serving Las Vegas and nearby areas.